LX6C Series PLC is high-performance medium-size controller, Based on the CODESYS platform.CODESYS allows for flexible programming and customization, enabling users to create and tailor their PLC code according to their specific needs.
Embedded I/Os reducing panel space costs.
Free, manufacturer-independent CODESYS programming environment.
It can be debugged remotely through the cloud platform V-Box / ig, V-IEC System.
Online editing, offline simulation, both are available on LX6C.
LX6C Model |
I/O |
Output Type |
RS485 |
Module |
Power Supply |
EtherCAT Axis |
EtherNet/IP |
MC |
OPC UA Server |
CNC |
ROBOTIC |
Webvisu |
LX6C-0808MT-DB |
08/08 |
Transistor |
2 |
YES |
DC |
16 |
YES |
YES |
N/A |
YES |
YES |
N/A |
LX6C-0808MT-DC |
08/08 |
Transistor |
2 |
YES |
DC |
32 |
YES |
YES |
N/A |
YES |
YES |
YES |
LX6C-0808MT-DD |
08/08 |
Transistor |
2 |
YES |
DC |
64 |
YES |
YES |
YES |
YES |
YES |
YES |
GENERAL
Model |
LX6C-0808MT |
|
Program Space |
Program Capacity |
5MB |
Variable Capacity |
10MB |
|
I Area (%I) |
128KB |
|
Q Area (%Q) |
128KB |
|
M Area (%M) |
512KB |
|
Power-down Latch Area |
1MB |
|
Programming Language |
LD / IL/ FBD / CFC / SFC / ST |
|
EtherNet |
Function |
Communication, debugging, uploading and downloading programs, firmware upgrade, etc. |
Data Transmission Speed |
1000Mbps / 100Mbps / 10Mbps |
|
Total TCP Connections |
Maximum 128 |
|
Modbus TCP |
Maximum 128 |
|
Socket |
Maximum 128 |
|
Cable |
Standard industrial Ethernet communication |
|
EtherNet/IP |
Server |
Maximum connections: 128 |
Client |
Maximum connections: 128 |
|
EtherCAT |
Transmission Speed |
100Mbsp(100Base-TX) |
Topology |
Bus type |
|
Cable |
Standard EtherCAT communication cable |
|
Maximum Transmission Distance Between the Nodes |
100 meters |
|
Maximum Number from Stations |
256 |
|
Maximum Process Data |
1380(maximum frame number is 1) |
|
Communication Cycle |
Minimum of 125μs It lasts for 1 minute. |
|
Support Protocol |
EtherCAT master |
|
USB |
Quantity |
1 channel TYPE-C interface |
Function |
RTC calibration, IP setting, firmware upgrade, etc. |
|
Specifications |
USB 2.0 |
|
RS485 |
Quantity |
2 |
Baud Rate (bps) |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
|
Maximum communication distance |
500m (9600 baud rate) |
|
Communication Mode |
Half duplex |
|
Support Protocol |
Modbus master/slave (RTU/ASCII), free communication protocol |
|
Topology |
Bus type |
|
Maximum Number of Slaves |
31 |
|
Power supply |
DC24V (±10%) |
|
Motion Control |
Support Version |
PLC OPEN Motion Control 2.0 |
G-code Capacity |
32M |
|
Robotic (Axis Group) |
Built-in 25 kinematic models, Maximum 8 axis groups (Maximum 6 axis interpolation per axis group) |
|
Expansion Module |
Maximum Number |
32 |
Host IO |
Input |
8 |
Output |
8 |