LX5V-2PTS-BD
2 X INPUT PT100 RTD precision >0.1°C
Model |
Channels |
Resolution |
Functionality |
LX5V-2PT-BD |
2 |
14 |
2 * Thermal Resistance Input |
LX5V-2PTS-BD |
2 |
14 |
2* Thermal Resistance Input, Precision >0.1℃ |
Specification
Item |
LX5V-2PT-BD |
Voltage input |
|
Digital circuit |
5VDC, 90mA (from the internal circuit of the main unit) |
Analog input signal |
Platinum thermal resistance PT100 sensor (100Ω), 3-wire 2-channel (CH1, CH2) |
Sensor current |
1mA |
Compensation range |
-100℃ to 600℃ |
Digital output |
-1000 to 6000 |
Measurement accuracy |
12-bit conversion 11 data bits +1 sign bit |
Measurement accuracy |
0.2℃ to 0.3℃ |
Total accuracy |
Full range ±1% (compensation range) |
Conversion speed |
2-channel 700ms |
Input features |
|
Item |
LX5V-2PTS-BD |
|
Power supply |
24VDC±10%, 50mA; 5VDC±10%, 70mA (The power supply is provided internally by host) |
|
Analog input signal |
Platinum thermal resistance PT100 sensor (100Ω), 3-wire 2-channel (CH1, CH2) |
|
Sensor current |
1mA |
|
Compensation range |
-190℃to600℃ (recommended range) |
Over range display: 32767 |
Digital output |
-2000to6100 (unit 0.1℃)—"maximum display range" |
|
Measurement accuracy |
16-bit conversion 15 data bits +1 sign bit |
|
Measurement accuracy |
0.05℃ |
|
Total accuracy |
Full range ±0.5% (compensation range) |
|
Conversion speed |
2 channels 50ms |
|
Conversion features |
|